Applications
In these cases, there is no separation between the air and the water inside the tanks. The energy stored in the form of pressurized air in the accumulator drives the water towards the consumption network. When the minimum pressure value is reached, the pump will start, creating a depression that will be solved by the injector taking air from the outside progressively until the maximum established pressure value is reached. At this moment, we will have the tank with the maximum volume of water and the pump will stop. As water consumption increases, the air that remains in the injector chamber is progressively supplied to the inside of the tank due to the depression produced inside it as the water level drops until pressures between suction and discharge are stabilized.
Series
DG
Characteristics
– Tanks without membrane made of hot-dip galvanized steel (inside and outside).
– Installed in combination with an injector unit.
– Maximum service pressure [bar]: 8 / 10
– Temperature [°C]: -10 / +100.
– CE certificate, in accordance with Directive 97/23/EC.